About Metravi 2010BA Classic Analogue Testing Meter
- Confirms to IEC61010-1, CAT II 1,000V, CAT III 500V to ground potential
- DC Voltage: 0-0.1/0.5/2.5/10/50/250/1000V
- Accuracy: 3%
- AC Voltage: 0-0.1/0.5/2.5/10/50/250/1000V
- Accuracy: 4%
- DC Current: 0-0.05/0.25/2.5/25/250mA/10A
- Accuracy: 3%
- AC Current: 0-0.05/0.25/2.5/25/250mA/10A
- Accuracy: 4%
- Resistance: 0 2k / 20k / 200k / 2M / 20M.Ohms
- Accuracy: 3%
- Battery Test: 1.5V / 9V
- Transistor Test, Diode Test and Continuity Test Facility
Superior Safety and ProtectionEquipped with IEC 61010-1 CAT II 1000V safety rating and fused protection for both current and voltage ranges, the Metravi 2010BA ensures user and equipment safety during various electrical tests. Its robust ABS build and overload protection further add to its durability and reliability.
User-Friendly OperationDesigned for convenience, this analogue testing meter features an integrated back stand for easy viewing, pointer zero adjustment, and traditional test lead interface. The auditory buzzer for continuity and dedicated diode test function simplify routine measurements for professionals and educators alike.
FAQ's of Metravi 2010BA Classic Analogue Testing Meter:
Q: How do I operate the Metravi 2010BA Classic Analogue Testing Meter?
A: To operate the meter, connect the included test leads to the device and set the range selector to the measurement type desired, such as voltage, current, resistance, continuity, or diode test. Use the pointer zero adjustment for accurate readings and refer to the user manual for guidance.
Q: What tests can the Metravi 2010BA perform?
A: This meter can measure AC and DC voltage up to 1000V, DC current up to 250mA, and resistance up to 2M. It also provides dedicated functions for diode testing and continuity checks with an audible buzzer.
Q: When should the batteries be replaced in the testing meter?
A: Replace the two AA batteries when the pointer or scale response becomes weak or unstable, ensuring optimal performance during measurements. The battery compartment is easily accessible for quick changes.
Q: Where is the Metravi 2010BA best suited for use?
A: The meter is ideal for general electrical measurements in educational environments, industrial workshops, and service tasks involving low voltage testing and troubleshooting.
Q: What is the process for ensuring accurate readings on this meter?
A: To ensure accuracy, set the pointer to zero using the adjustment dial before every measurement. Select the appropriate range and avoid exceeding the specified maximum values. Always adhere to safety protocols described in the user manual.
Q: How does the integrated back stand benefit users?
A: The integrated back stand enables hands-free viewing, allowing users to easily monitor readings while performing checks or adjustments, thereby increasing convenience and reducing error risk.