About Metravi 50-MOTS Motorised Oil Test Set
- It is ideal for speedy and accurate testing of di-electric strength of transformer and circuit beaker oil under test room condition in accordance with IS:6792-1972 for oil testing.
- Input: 230V Single Phase AC 50Hz.
- Output: Continuously variable from 0 to 50kV AC with centre point of the HV winding earthed
- Capacity: Spread over a range from 500VA to 1200VA depending on the output voltage
- Duty: Intermittent duty cycle
- Nature of Cooling: The transformer is cast resin type air cooled
- Motor Operated
Key Features and Precision EngineeringThis Motorised Oil Test Set integrates transparent polycarbonate oil cups with stainless steel electrodes, ensuring durability and faultless contact during testing. Its programming supports preset test cycles conforming to IS 6792/IEC 156 standards, and the apparatus includes safety measures such as earth leakage circuit breaker and interlocking covers. The digital display and auto-stop at breakdown enhance accuracy and operational safety.
Efficient Operation and Flexible ControlThe instrument supports both automatic and manual operation modes to accommodate a range of testing needs. Its fast 2.0 kV/s test speed and single 400 ml oil sample capacity streamline the process, making it suitable for laboratory and industrial applications. Optional external output to printer or PC allows for easy data management and record-keeping.
Built for Safety and ComplianceEngineered in accordance with IS 6792 and IEC 60156, the Metravi 50-MOTS prioritizes user safety through features like transparent safety cover, earth leakage breaker, and an automatic shutdown at breakdown. The bench-top design and robust build make it ideal for high-volume test environments, while natural air cooling maintains optimal operating temperature.
FAQ's of Metravi 50-MOTS Motorised Oil Test Set:
Q: How does the Metravi 50-MOTS Motorised Oil Test Set measure transformer oil breakdown voltage?
A: The equipment measures breakdown voltage by applying a steadily increasing voltage to the oil sample. The digital LED display clearly indicates the voltage at which dielectric breakdown occurs, and an instantaneous auto-stop ensures accuracy and safety.
Q: What safety features are included in the Metravi 50-MOTS for operator protection?
A: Key safety features include an earth leakage circuit breaker, a transparent interlocking cover that prevents accidental exposure, and an automatic shutdown function upon oil breakdown. These ensure safe operation during tests.
Q: When should the oil test set be used in a laboratory or industrial setting?
A: This equipment is ideal for routine checks of transformer oil in laboratories, substations, maintenance facilities, and manufacturing plants, especially when monitoring oil dielectric integrity is critical for operational reliability.
Q: Where can test data from the Metravi 50-MOTS be exported or accessed?
A: Test results can be stored on the digital display, and with the optional printer or PC interface, results can also be exported and archived for traceability and analysis.
Q: What is the process of conducting a dielectric breakdown test with this device?
A: Fill the test cup with a 400 ml oil specimen, secure the transparent safety cover, set the control mode (automatic or manual), and start the test. The instrument will ramp up voltage until breakdown is detected, then automatically record and display the result.
Q: How does the Metravi 50-MOTS benefit operators in high-volume testing environments?
A: With fast test cycles, automated detection, intuitive controls, and robust safety mechanisms, the device enables efficient, repeatable, and safe testing, reducing operator workload and ensuring compliant results every time.