About Metravi 50-OTS Motorised Oil Test Set
- It is ideal for speedy and accurate testing of di-electric strength of transformer and circuit beaker oil under test room condition in accordance with IS:6792-1972 for oil testing.
- Input: 230V Single Phase AC 50Hz.
- Output: Continuously variable from 0 to 50kV AC with centre point of the HV winding earthed
- Capacity: Spread over a range from 500VA to 1200VA depending on the output voltage
- Duty: Intermittent duty cycle
- Nature of Cooling: The transformer is cast resin type air cooled
- Manually Operated
Precise Breakdown Voltage TestingThe Metravi 50-OTS streamlines the process of testing dielectric strength in transformer and insulating oils. Its motorized operation and automatic control remove manual errors, while the adjustable electrode gap caters to various test standards. The device provides instant readings with high accuracy, and the large digital LCD display ensures clear result visualization.
Compliant and Reliable DesignBuilt to meet IS:6792 and IEC-156 international standards, the unit features a factory-calibrated measuring system and includes all necessary accessories such as test electrodes, a test cup, and a sturdy carry case. Safety is prioritized with built-in overload and earth leakage protection, ensuring secure operation for frequent laboratory and on-site testing.
FAQ's of Metravi 50-OTS Motorised Oil Test Set:
Q: How does the Metravi 50-OTS Motorised Oil Test Set measure the dielectric breakdown voltage of oil samples?
A: The device automatically applies a controlled, increasing voltage across a sample of insulating oil placed between adjustable brass electrodes. The test continues until the breakdown voltage point is detected, and the digital LCD displays the precise voltage at which insulation fails.
Q: What safety features are included in the Metravi 50-OTS Oil Test Set?
A: The set is equipped with overload and earth leakage protection, along with over-voltage protection, to ensure user safety during operation. Its transparent, high-grade plastic test container also allows safe visual inspection of the testing process.
Q: When should I use this oil test set for transformer or insulating oils?
A: This test set should be used during routine or preventive maintenance, new oil commissioning, or after any major electrical event. Regular testing ensures that transformer and insulating oils maintain their dielectric properties, preventing equipment failures.
Q: Where can the Metravi 50-OTS be used, and what are its installation requirements?
A: It is suitable for laboratory or on-site environments, requiring only a bench-top for installation and a standard 230V AC, 50Hz power supply. The IP20 protection class is designed for indoor conditions, and the set operates effectively in ambient temperatures up to 40C and humidity levels up to 80% RH.
Q: What is the process for conducting an oil test with this equipment?
A: Begin by placing the oil sample in the provided test cup, adjusting the electrode gap as per requirements. Use the manual interface to start the automated test. The motorized operation will ramp the voltage and automatically stop at breakdown, with the result shown on the digital display.
Q: How does using this instrument benefit regular maintenance or oil quality checks?
A: The Metravi 50-OTS offers precise, repeatable results, reducing human error and ensuring compliance with international testing standards. Automatic operation, instant response time, and clear digital results streamline maintenance workflows, helping to prevent equipment damage and downtime.