Call UsCall Us : 08071931506
Metravi 506 Digital LCR Meter with Multimeter Dual Extra Large LCD
Metravi 506 Digital LCR Meter with Multimeter Dual Extra Large LCD

Metravi 506 Digital LCR Meter with Multimeter Dual Extra Large LCD

Price 20827.00 INR/ Piece

MOQ : 1 Piece

Metravi 506 Digital LCR Meter with Multimeter Dual Extra Large LCD Specification

  • Interface Type
  • Standard Banana Jack & Probe
  • Features
  • Auto/Manual L, C, R range selection, Data hold, Auto power-off, Continuity & Diode test
  • Response Time
  • Fast measurement conversion
  • Mounting Type
  • Portable, Handheld
  • Frequency
  • Test frequency: 1kHz (LCR functions)
  • Application
  • Measuring L, C, R, DCR, DC Voltage, AC Voltage, DC/AC Current, and Diode/Continuity
  • Specimen Size
  • Component Level
  • Resolution
  • High resolution up to 0.1H/0.1pF/0.1
  • Humidity
  • <80% Relative Humidity
  • Display Type
  • Dual Extra Large LCD Display
  • Temperature
  • Operating: 0C to 40C
  • Automation Grade
  • Manual
  • Accuracy
  • (0.5% reading + 2 digits) (Resistance)
  • Port Size
  • Standard Input Jacks & LCR Terminals
  • Power Supply
  • 9V Battery
  • Test Range
  • Resistance: 200 to 20M, Capacitance: 2nF to 200F, Inductance: 2mH to 20H
  • Operating Voltage
  • Passive measurement, Powered by 9V Battery
  • Number of Specimens
  • Single Device Test
  • Measuring Range
  • L: 2mH-20H; C: 2nF-200F; R: 200-20M
  • Usage
  • Field and laboratory measurement of electrical components
  • Capacity
  • Max Capacitance 200F
  • Machine Weight
  • Approx. 500g
  • Test Speed
  • Manual/auto selection
  • Control Mode
  • Manual
  • Data Hold Function
  • Yes
  • Input Impedance
  • >10M (VDC)
  • Continuity Test
  • Yes, with beep
  • Product Dimension
  • 180 x 90 x 41mm
  • Equipment Type
  • Digital LCR Meter with Multimeter
  • Safety Category
  • CAT II 1000V
  • Overload Protection
  • Yes (Fused)
  • Diode Test
  • Yes
  • Display Size
  • Dual 22mm LCD Panels
  • Auto Power Off
  • Yes (to save battery life)
  • Low Battery Indication
  • Yes
  • Multimeter Functions
  • DC Voltage: 200mV-1000V, AC Voltage: 200V-750V, Current: 200A-20A
  • Max Display Count
  • 1999 (3 Digit)
 

Metravi 506 Digital LCR Meter with Multimeter Dual Extra Large LCD Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID), Cheque, Cash Advance (CA)
 

About Metravi 506 Digital LCR Meter with Multimeter Dual Extra Large LCD

Metravi 506 Digital LCR Meter with Multimeter Specifications:

  • Display : 3-3/4 Digits Backlit 3999 Counts
  • Dual Extra Large LCD
  • DC Voltage : 0 400mV/4V/40V/400V/1000V
  • Accuracy : 0.3%
  • AC Voltage : 0 400mV/4V/40V/400V/750V T-RMS.
  • Accuracy : 1.0%
  • DC Current : 0 400uA/400mA/20A.
  • Accuracy : 1.0%
  • AC Current : 0 400uA/400mA/20A T-RMS.
  • Accuracy : 1.5%
  • Resistance : 0 400/4k/40k/400k/4M/40M.Ohms
  • Accuracy : 0.5%
  • Capacitance : 0 100uF
  • Accuracy : 3.0%
  • Frequency : 0 10 kHz/100kHz/1MHz/10MHz
  • Accuracy : 0.01%
  • Inductance : 0 20/50/100H
  • Accuracy : 3.0%
  • Duty Cycle : 0.1% 99.9%
  • Accuracy : 1.2%
  • Temperature: -20C+1200C / 0F+2000F
  • Accuracy : 3%
  • dBm : -25dBm to + 59dBm
  • Accuracy : 0.5dBm
  • Logic Test, Diode Test, Signal Output and Audible Continuity test facility.
  • Confirms to UL 1244 AND VDE-0411
  • Complete with carrying case, instruction manual, test leads, battery, RS-232C PC Interface cable and software.


Dual Display for Enhanced Readability

Equipped with extra-large dual 22mm LCD panels, the Metravi 506 Digital LCR Meter ensures visibility of readings in all environments. This feature simplifies the measurement process and helps users simultaneously track multiple parameters, facilitating efficient field and laboratory assessments.


Comprehensive Multimeter Functions

Alongside LCR measurements, the meter also supports multimeter operations, including DC voltage (up to 1000V), AC voltage (up to 750V), and current (up to 20A). Integrated continuity and diode tests with audible alerts further expand its utility for component troubleshooting.


Reliable Protection and Power Management

Safety is ensured with CAT II 1000V rating and fused overload protection. The device includes an auto-power-off feature to conserve battery life and a low battery indicator, making it a robust choice for prolonged use in diverse settings.

FAQs of Metravi 506 Digital LCR Meter with Multimeter Dual Extra Large LCD:


Q: How do I use the data hold function on the Metravi 506 LCR Meter?

A: To activate the data hold function, press the designated Hold button during measurement. This freezes the displayed value, allowing you to record or analyze the reading even after disconnecting the test leads.

Q: What types of electrical components can the Metravi 506 measure?

A: The Metravi 506 Digital LCR Meter is suitable for testing inductors, capacitors, resistors, as well as diodes and continuity in component-level devices. It provides accurate measurements of L, C, R, DCR, voltage, current, and performs diode and continuity tests with audible alerts.

Q: When should I replace the 9V battery in my meter?

A: You should replace the 9V battery when the low battery indication appears on the display. This ensures the device continues to operate reliably without interruptions or inaccurate readings caused by insufficient power supply.

Q: Where can I use the Metravi 506 Digital LCR Meter?

A: This handheld, portable meter is designed for use in laboratories, workshops, and field environments. Its robust construction, clear dual LCD display, and protective features make it suitable for both indoor and outdoor electrical measurements.

Q: What safety features does the meter provide during measurements?

A: The Metravi 506 is equipped with overload protection via fused circuits and adheres to CAT II 1000V safety standards. These features help prevent damage to both the meter and the user during high-voltage or erroneous connections.

Q: How does the auto power-off function benefit users?

A: The auto power-off feature saves battery life by automatically switching off the device after a period of inactivity. This is especially useful during extended use in the field, preventing accidental battery depletion.

Q: What is the test process for measuring capacitance, resistance, or inductance?

A: To measure these parameters, select the desired mode using the control dial, connect the specimen via LCR terminals, and read the value on the dual LCD display. Manual and auto range selection enable fast, accurate test results, and high resolution aids in detailed diagnostics.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in LCR Meters Category

SMT-01 SMT Component Tester

SMT-01 SMT Component Tester

Price 4543.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : For resistance, capacitance, inductance SMT chip testing

Resolution : 0.01

Humidity : 85% RH

Frequency : 50/60 Hz

Metravi 451 Digital Multimeter with LCR Measurement

Metravi 451 Digital Multimeter with LCR Measurement

Price 3717.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Electrical & Electronic Testing

Resolution : Manual Range Selection

Humidity : <75% RH

Frequency : 50Hz/60Hz (Related to AC Voltage Measurement)

Metravi 4070D Handheld Digital LCR Tester

Metravi 4070D Handheld Digital LCR Tester

Price 13393.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Testing inductance, capacitance, resistance, component sorting, and quality control

Resolution : Max: 0.1H/0.1pF/0.01

Humidity : <80% RH

Frequency : Test frequencies: 100Hz, 120Hz, 1kHz, 10kHz

Metravi 460 Digital Hand-held LCR Meter

Metravi 460 Digital Hand-held LCR Meter

Price 6077.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Inductance, Capacitance, and Resistance Measurement

Resolution : 0.1H (L), 0.1pF (C), 0.1 (R)

Humidity : 80% RH (noncondensing)

Frequency : Test frequencies: 100Hz, 120Hz, 1kHz, 10kHz