About Metravi 75-MOTS Motorised Oil Test Set
- It is ideal for speedy and accurate testing of di-electric strength of transformer and circuit beaker oil under test room condition in accordance with IS:6792-1972 for oil testing.
- Input: 230V Single Phase AC 50Hz.
- Output: Continuously variable from 0 to 75kV AC with centre point of the HV winding earthed
- Capacity: Spread over a range from 500VA to 1200VA depending on the output voltage
- Duty: Intermittent duty cycle
- Nature of Cooling: The transformer is cast resin type air cooled
- Motor Operated
Advanced Safety and Automation FeaturesThe device integrates multiple safety mechanisms such as a transparent shield, safety interlock, and automatic cut-off after breakdown detection. Its motorised control and push button panel promote user convenience and operational safety, minimizing human error and exposure risk during testing.
Accurate and Reliable Breakdown Voltage TestingUtilizing a standard-sized oil cup and precise measuring range from 0 to 75 kV, the Metravi 75-MOTS guarantees consistent, accurate measurement of dielectric strength in transformer oils. With instant digital display and memory retention, users benefit from dependable results and seamless repeat testing.
FAQ's of Metravi 75-MOTS Motorised Oil Test Set:
Q: How do you operate the Metravi 75-MOTS Motorised Oil Test Set?
A: Simply place a standard transformer oil sample into the high-grade insulating cup, set the desired test parameters using the push button control panel, and initiate the test. The automatic start/stop functionality and motorised control guide the process, ensuring consistent oil testing.
Q: What is the primary function of this oil test set?
A: The Metravi 75-MOTS is engineered to measure the dielectric breakdown voltage of transformer oils, determining their insulation properties and suitability for electrical applications as per IS and IEC standards.
Q: Where can the Metravi 75-MOTS equipment be used?
A: This instrument is ideal for laboratory and industrial settings, particularly in manufacturing, maintenance, and quality control environments, and is suitable for bench-top mounting.
Q: When should transformer oils be tested with the 75-MOTS set?
A: Transformer oils should be tested periodically or before use to verify electrical insulation integrity, especially during equipment commissioning, routine maintenance, or after suspected contamination.
Q: What is the process for testing oil breakdown voltage using this device?
A: Fill the cup with a 15 ml oil specimen, select the test speed and voltage range on the control panel, activate the automatic test, and observe the digital readout for breakdown voltage. The system auto-cuts off after breakdown and retains the last test value for reference.
Q: What are the usage benefits of the Metravi 75-MOTS Oil Test Set?
A: Users benefit from automation, high safety features, accurate and instantaneous results, last test value memory, and internal calibration, enabling efficient and reliable assessments of transformer oil quality.
Q: How does the auto cut-off and safety shield protect users during testing?
A: The transparent shield provides a physical barrier, while the auto cut-off feature immediately stops the high voltage supply upon oil breakdown, protecting users from accidental exposure and equipment damage.