About Metravi Calibrator
- Hand Held , 9V battery Operated
- 4 Digits 19999 Counts LCD Display
- Sources :-
- DC voltage : 0- 199.99mV
- Accuracy : 0.05%
- DC Current : 0 - 19.999mA
- Accuracy : 0.05%
- Measures :-
- DC voltage : 0- 199.99mV
- Accuracy : 0.05%
- DC Current : 0 - 19.999mA
- Accuracy : 0.05%
- Output adjustable : By 10 Turn POT for COARSE AND FINE
Accurate Performance for Industrial ApplicationsEngineered for reliability, the Metravi Calibrator delivers high accuracy (0.05%+2d) and fine resolution (0.001). Its source and simulate capabilities for current and voltage make it ideal for process calibration and automation setups. The device is optimal for use in environments requiring precision and repeatability.
Designed for Portability and Ease-of-UseWeighing only 322g and measuring compactly, the calibrator is both lightweight and durable, featuring a protective carry case. The manual control mode ensures hands-on flexibility, while the large LCD with backlight enhances visibility. Its handheld mounting type allows quick field deployment.
Extended Battery Life and Safety FeaturesWith more than 30 hours of operation per battery (without backlight), the calibrator supports long fieldwork sessions. Overload protection safeguards the device during demanding tasks. The loop power capability up to 24V makes it suitable for powering and testing process indicators and transmitters directly.
FAQ's of Metravi Calibrator:
Q: How do I use the Metravi Calibrator for process calibration tasks?
A: To perform process calibration, connect the calibrator to your instrumentation using the 4mm banana jack interface. Select the desired mode (source, measure, or simulate) and set your required current or voltage. The device offers a manual control mode for precise adjustments.
Q: What applications is the Metravi Calibrator most suitable for?
A: This calibrator is ideal for process control, instrumentation, and field calibration tasks. It is widely used for current and voltage generation, troubleshooting automation setups, and periodic calibration of sensors and transmitters.
Q: When is the large backlit display beneficial during operation?
A: The backlit display is particularly useful in low-light conditions or environments where visibility is limited. It ensures that readings are clear and accurate at all times, enhancing usability during night shifts or dimly lit field locations.
Q: Where can I use the Metravi Calibrator, considering its operating environment?
A: The device can be used wherever precision current or voltage calibration is needed, and it works optimally within temperature ranges from 0C to 50C and humidity less than 80% RH. Its handheld form and carry case make it suitable for both in-field and laboratory use.
Q: What is the process for switching between source, measure, and simulation modes?
A: Switching between modes is done manually. Use the front panel controls to toggle between source, measure, and simulation; this allows you to generate, measure, or simulate electrical signals according to your calibration requirements.
Q: How does overload protection benefit the use of the calibrator?
A: Overload protection helps prevent damage to the device and connected equipment when unexpected surges or improper connections occur. This safety feature maintains calibrator integrity during rigorous industrial applications.