Call UsCall Us : 08071931506
Metravi CET-04 Clamp On Ground Resistance Tester
Metravi CET-04 Clamp On Ground Resistance Tester

Metravi CET-04 Clamp On Ground Resistance Tester

Price 33217.00 INR/ Piece

MOQ : 1 Piece

Metravi CET-04 Clamp On Ground Resistance Tester Specification

  • Automation Grade
  • Manual
  • Application
  • Measurement of ground resistance and leakage current
  • Humidity
  • 85% RH (non-condensing)
  • Power Supply
  • 6V DC (4 x 1.5V AA batteries)
  • Operating Voltage
  • 6V DC
  • Number of Specimens
  • Single point test
  • Response Time
  • Approx. 2 seconds
  • Equipment Type
  • Clamp On Ground Resistance Tester
  • Measuring Range
  • 0.010 to 1200 (resistance), 0.00 to 20.00A (current)
  • Test Range
  • 0.010 to 1200 (resistance), 0.00 to 20.00A (current)
  • Frequency
  • 50/60 Hz
  • Features
  • Auto power off, data hold, audible alarm, store/recall readings
  • Accuracy
  • 1.5% 0.01 (1-99.9 ), 5% (100-1200 )
  • Resolution
  • 0.001
  • Display Type
  • Large LCD digital display
  • Max Height
  • 231 mm length
  • Temperature
  • 0C to 40C (operating)
  • Mounting Type
  • Handheld/Portable
  • Specimen Size
  • Conductor 1 mm diameter
  • Usage
  • Electrical safety testing
  • Machine Weight
  • 1.65 kg
  • Test Speed
  • Approx. 0.5 seconds per test
  • Test Width
  • 32 mm jaw opening
  • Control Mode
  • Manual
  • Dimensions
  • 285 × 85 × 56 mm
  • Model Number
  • CET-04
  • Auto Power Off
  • Yes
  • Safety Category
  • CAT III 300V
  • Alarm Function
  • Audible and visible alarm
  • Calibration
  • Factory calibrated
  • Jaw Opening Size
  • 32 mm (maximum conductor size)
  • Data Storage
  • Records up to 99 sets
 

Metravi CET-04 Clamp On Ground Resistance Tester Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 7 Days
 

About Metravi CET-04 Clamp On Ground Resistance Tester

  • Widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment.
  • Can measure the leakage current of ground wire. Clamp Earth Resistance Tester measures the integrated value of ground resistance and resistance lead.
  • When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster.
  • Clamp Earth Resistance Tester can measure the ground fault which can not be measured by traditional method, can apply in the occasion where traditional methods are unworkable.
  • The latest updated series Clamp Earth Resistance Testers have better performance: Boot up instantly, avoid boot up errors; More reliable battery cover, convenient to change battery; Wider range, larger memory; Optional RS232 interface, available to transfer data to PC and generate report files, easy to analyse or backup data.
  • Clamp Jaw: 32mm
  • Display: 4 digit Backlit LCD
  • Resistance Range: 0.01 to 1500
  • Resolution: 0.01 Ohms
  • Current range:0.00-20.00A
  • Resolution: 0.05mA
  • Auto Ranging
  • Storage of Measured Data: 99 Data
  • Setting of Resistance Alarm Critical Value: 1 199 Ohms
  • Setting Range of Current Alarm Critical Value1-499mA
  • Data Hold, Auto Power Off


High-Precision Ground Resistance Testing

Metravi CET-04 delivers accurate results with a wide resistance range from 0.010 to 1200 and current up to 20.00A. Its 1.5% basic accuracy and high 0.001 resolution make it suitable for stringent safety checks. The testers factory calibration ensures reliable output, meeting the demands of engineers, technicians, and safety inspectors alike.


Efficient Data Management and Alerts

Capable of recording up to 99 readings, the CET-04 simplifies documentation and monitoring over time. Audible and visual alarms instantly inform users of abnormal readings, enhancing onsite safety and operational efficiency. Simply store and recall important data at the push of a button.


Designed for Versatile Field Use

The clamp-on design with a 32 mm jaw opening allows for quick, contactless measurement on live systems without service interruption. Its portable, handheld construction, auto power off, and clear digital display make it indispensable for electrical safety testing, equipment maintenance, and troubleshooting in demanding environments.

FAQs of Metravi CET-04 Clamp On Ground Resistance Tester:


Q: How does the Metravi CET-04 Clamp On Ground Resistance Tester operate?

A: The CET-04 operates by clamping around a conductor (minimum diameter 1 mm) and measuring ground resistance or leakage current without disconnecting the circuit. The device utilizes advanced electronics to deliver fast and accurate results within approximately 0.5 to 2 seconds per test.

Q: What types of applications is the CET-04 suitable for?

A: This tester is ideal for measurement of ground resistance and leakage current in power distribution networks, grounding systems, electrical safety installations, and equipment maintenanceproviding both reliability and ease of use in industrial and commercial settings.

Q: When should I use the data storage function of this tester?

A: You should use the data storage feature when conducting multiple tests in a session, performing comparative analysis, or keeping compliance records. The CET-04 can record and recall up to 99 sets of readings, which helps in accurate tracking over time.

Q: Where is the CET-04 best utilized for optimal performance?

A: The CET-04 is optimized for use in environments where electrical safety is critical, such as substations, manufacturing plants, and construction sites. It is especially useful in scenarios where disconnection is not feasible or time-consuming, offering non-intrusive testing.

Q: What is the calibration process for this device?

A: The CET-04 comes factory calibrated, which ensures measurement accuracy fresh out of the box. Users do not need to perform any additional calibration before using the device, making it convenient for immediate deployment.

Q: How can I benefit from the alarm and auto power-off features?

A: The audible and visible alarm functions alert you immediately to unsafe readings, enhancing onsite safety. Auto power-off conserves battery life, ensuring the tester is ready for extended field use.

Q: What are the power requirements and maintenance tips for the CET-04?

A: The tester operates on 6V DC supplied by four 1.5V AA batteries. To ensure long-term operation, use quality batteries and replace them when indicated. Store the device in a dry, cool place, and avoid exposure to high humidity or extreme temperatures to maintain optimal performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Earth Ground Resistance Tester Category

Metravi CET-06 Clamp On Ground Resistance Tester

Metravi CET-06 Clamp On Ground Resistance Tester

Price 25193.00 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : 4digit LCD Digital Display with Backlight

Resolution : 0.001 (Resistance), 0.01mA (Current)

Usage : Electrical Earth Testing

Temperature : 0C to 50C

Metravi CET-05 Clamp On Ground Resistance Tester

Metravi CET-05 Clamp On Ground Resistance Tester

Price 25193.00 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : Large LCD Digital Display with backlight

Resolution : 0.01 (1m)

Usage : Testing ground resistance and leakage current clamps

Temperature : Operating: 10C to 55C

Metravi ERT-1502 Digital Resistance Earth Tester

Metravi ERT-1502 Digital Resistance Earth Tester

Price 9027.00 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : Large backlit LCD display

Resolution : 0.01

Usage : Earth resistance measurement

Temperature : 0C to 40C

Metravi CET-01 Clamp On Ground Resistance Tester

Metravi CET-01 Clamp On Ground Resistance Tester

Price 29677.00 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : LCD Digital Display

Resolution : 0.01 (Resistance); 0.01mA (Current)

Usage : For testing earth/ground resistance and leakage current measurement without breaking the circuit

Temperature : 0C to 50C