Call UsCall Us : 08071931506
Metravi Metrasafe-16 True RMS Digital Multimeter
Metravi Metrasafe-16 True RMS Digital Multimeter

Metravi Metrasafe-16 True RMS Digital Multimeter

Price 7847.00 INR/ Piece

MOQ : 1 Piece

Metravi Metrasafe-16 True RMS Digital Multimeter Specification

  • Mounting Type
  • Handheld
  • Humidity
  • 85% RH (non-condensing)
  • Equipment Type
  • True RMS Digital Multimeter
  • Temperature
  • 0C ~ 40C
  • Power Supply
  • 9V Battery (6F22)
  • Features
  • True RMS, Auto/Manual Range, Data Hold, Backlight, Max/Min, NCV, Continuity Buzzer, Temperature Measurement, Diode Test
  • Automation Grade
  • Manual
  • Accuracy
  • (1.0%+3) for DCV Basic
  • Frequency
  • 9.999Hz ~ 9.999MHz
  • Resolution
  • 6000 counts
  • Application
  • Electrical and Electronic Measurements
  • Test Range
  • Depends on Function (Refer Measuring Range)
  • Measuring Range
  • ACV: 600mV/6V/60V/600V/1000V; DCV: 600mV/6V/60V/600V/1000V; ACA: 600A/6000A/60mA/600mA/6A/10A; DCA: 600A/6000A/60mA/600mA/6A/10A; Resistance: 600/6K/60K/600K/6M/60M; Capacitance: 10nF/100nF/1F/10F/100F/1mF/10mF/100mF; Frequency: 9.999Hz ~ 9.999MHz; Temperature: -40C ~ 1000C
  • Display Type
  • LCD with Backlight
  • Usage
  • Electrical Testing & Diagnostics
  • Machine Weight
  • Approx. 390g (with battery)
  • Operating Environment
  • 0C~40C, 85% RH
  • Max Display
  • 5999 (6000 Counts)
  • Sampling Rate
  • 3 times/sec
  • Non-Contact Voltage (NCV)
  • Yes
  • Low Battery Indication
  • Yes
  • Storage Environment
  • -20C~60C, 85% RH
  • Dimension
  • 186 x 86 x 40 mm
  • Model
  • Metrasafe-16
  • Backlight
  • Yes
  • Input Impedance
  • Approx. 10M (for V)
  • Input Protection
  • Yes
  • Safety Rating
  • CAT IV 600V, CAT III 1000V
  • Continuity Check
  • Audible Buzzer
  • Data Hold
  • Yes
  • Diode Test
  • Yes
  • Fuse Protection
  • Yes (Fuse: F10A/600V)
  • Battery Type
  • 9V Battery (6F22)
 

Metravi Metrasafe-16 True RMS Digital Multimeter Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID), Cheque, Cash Advance (CA)
 

About Metravi Metrasafe-16 True RMS Digital Multimeter

  • Fully Protected DMM
  • 1200V DC/AC RMS Protection in Voltage Ranges
  • 20A DC/AC RMS Protection in Ampere Ranges
  • 600V DC/AC RMS Protection in Resistance, Capacitance, Frequency, Temperature, Continuity and Diode Test Ranges
  • Surge Protection of 8kV Peak IEC61010
  • O Ring Seal Body
  • T-RMS measurement, Peak Hold, Relative Measuring
  • MAX / MIN Recording,
  • Auto Power Off
  • Display: 3- Digits 4000 Counts Backlit LCD with Analog Bargraph
  • DC Voltage: 0 400mV/4V/40V/400V/1000V
  • Accuracy: 0.5%
  • AC Voltage: 0 400mV/4V/40V/400V/1000V T-RMS
  • Accuracy: 0.8%
  • DC Current: 0 400uA/4000uA/40mA/400mA/20A
  • Accuracy: 1.2%
  • AC Current: 0 400uA/4000uA/40mA/400mA/20A T-RMS
  • Accuracy: 1.5%
  • Capacitance: 0 4nF/40nF/400nF/4uF/40uF/400uF/4mF/40mF
  • Accuracy: 3%
  • Frequency: 0 4kHz/40KHz/400KHz/40MHz
  • Accuracy: 1.2%
  • Temperature: -20C to +760C / -4F to +1400F
  • Accuracy: 3%
  • Diode Test and Audible Continuity Test
  • Confirms to CAT-III 1000V, CAT-IV 600V, EN61010-1, CE


Comprehensive Measurement Capabilities

The Metrasafe-16 delivers versatile measurement options including AC/DC voltage and current, resistance, capacitance, frequency, diode testing, and temperature, supporting a broad spectrum of diagnostic needs in a single compact device. True RMS technology ensures higher accuracy even with non-sinusoidal signals.


Rugged Design and User-Friendly Features

Built for durability, this multimeter withstands challenging field conditions. Essential features like a data hold, audible continuity buzzer, LCD backlight, and an ergonomic form factor make it user-friendly. The unit offers a straightforward interface and clearly visible readings up to 6000 counts, enhancing on-the-go usability.


Enhanced Safety and Protection

Safety is paramount in the Metrasafe-16, which holds CAT IV 600V and CAT III 1000V safety ratings. Integrated fuse protection and input safeguards minimize risks during high-voltage tasks, while NCV (Non-Contact Voltage) detection further elevates user security during diagnostics.

FAQ's of Metravi Metrasafe-16 True RMS Digital Multimeter:


Q: How does the Metravi Metrasafe-16 ensure accurate measurements?

A: The Metrasafe-16 uses True RMS technology, which provides precise AC and DC measurements even with non-sinusoidal waveforms. Its resolution of 6000 counts and (1.0%+3) accuracy for DCV ensures reliable results across a variety of electrical parameters.

Q: What is the process for continuity testing with the Metrasafe-16?

A: Continuity testing is simple: select the continuity test function, connect the probes to the circuit, and listen for the audible buzzer, which indicates if the circuit is complete. This feature streamlines diagnostics and troubleshooting.

Q: When should I use the Non-Contact Voltage (NCV) feature?

A: The NCV feature is ideal for quickly identifying the presence of live voltage in wires and outlets without direct contact, enhancing user safety during initial diagnostics or before making detailed measurements.

Q: Where can the Metrasafe-16 be safely operated and stored?

A: It can be used in environments ranging from 0C to 40C and 85% RH. For storage, ensure the temperature is between -20C and 60C. The non-condensing humidity rating further protects the meter in diverse climates.

Q: How does the data hold function benefit users during measurement?

A: The data hold function temporarily stores the most recent measurement on the display, allowing users to record or observe the value even if they need to move the meter or adjust its position.

Q: What are the main safety benefits of the Metrasafe-16?

A: With safety ratings of CAT IV 600V and CAT III 1000V, as well as integrated fuse and input protection, users are safeguarded against electrical hazards during high-voltage or industrial testing scenarios.

Q: Can the Metrasafe-16 measure temperature, and how is this accomplished?

A: Yes, it measures temperature within a range of -40C to 1000C. Set the function to temperature, attach the thermocouple probe, and place it on the surface or substance to obtain an accurate temperature reading.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Process Meter Category

Metravi AVM-05 Air Velocity & Volume Measurement Anemometer

Metravi AVM-05 Air Velocity & Volume Measurement Anemometer

Price 8201.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Measurement of air velocity, temperature, humidity & air volume

Usage : Air flow measurement in HVAC, environmental testing, industrial air monitoring

Measuring Range : Air Velocity: 0.3~45 m/s; Air Volume: 0~99999 CMM / 0~99999 CFM

Operating Voltage : 9V DC battery

Metravi CE-0304IM Three Phase Integrated Meter

Metravi CE-0304IM Three Phase Integrated Meter

Price 6962.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Energy measurement in three phase systems

Usage : Commercial, Industrial, Utility Metering

Measuring Range : 0999999.99 kWh

Operating Voltage : 3 x 230/400V AC

Metravi RNT-5 Relay Test Set

Metravi RNT-5 Relay Test Set

Price 33689.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Testing electromagnetic relays and associated control circuits

Usage : Relay Testing

Measuring Range : 0 250V AC / DC, 0 5A AC / DC

Operating Voltage : 230V AC, 50 Hz

Metravi 276HD Contact-Type High Voltage Detector

Metravi 276HD Contact-Type High Voltage Detector

Price 16697.00 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Detection of high voltage presence in power lines, switchgears, and busbars

Usage : High Voltage Presence Testing

Measuring Range : 6 kV to 76 kV AC (Nominal)

Operating Voltage : 6~76 kV AC (50/60Hz)