Call UsCall Us : 08071931506
Metravi 03+ RTD Calibrator
Metravi 03+ RTD Calibrator

Metravi 03+ RTD Calibrator

Metravi 03+ RTD Calibrator Specification

  • Display Type
  • LCD Digital Display
  • Humidity
  • 80% RH
  • Accuracy
  • 0.3C
  • Response Time
  • <2 seconds
  • Equipment Type
  • RTD Calibrator
  • Mounting Type
  • Handheld
  • Power Supply
  • 9V Battery (PP3/NEDA 1604/006P)
  • Interface Type
  • 4mm Banana Sockets
  • Application
  • RTD Simulation and Calibration
  • Features
  • Handheld, Portable, Direct and Step Output Function, Designed for RTD Transmitter/Indicator Calibration
  • Measuring Range
  • -200C to +850C (as per RTD type)
  • Automation Grade
  • Manual
  • Operating Voltage
  • 9V
  • Temperature
  • 0C to 50C
  • Resolution
  • 0.1C
  • Usage
  • Laboratory, Field Calibration, Industrial Use
  • Machine Weight
  • Approx. 350g
  • Control Mode
  • Manual
  • Dimensions
  • 180 x 90 x 47 mm
  • Reference Standard
  • IEC751 (for Pt100)
  • Output Connection
  • 4-Terminal
  • Compliance
  • CE Certified
  • Overload Protection
  • Yes
  • Output Types Supported
  • Pt100, Pt200, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni120
  • Output Modes
  • Direct and Step
  • Battery Life
  • Approx. 40 hours continuous
  • Low Battery Indication
  • Yes
  • Operating Environment
  • Indoor/Outdoor
  • Storage Temperature
  • -20°C to 60°C
 
 

About Metravi 03+ RTD Calibrator

Simulates thermo Resistance and resistance output
Measures thermo-resistance and resistance
C and F scales selectable
Suitable for field use
High Accuracy of 0.05%
Display  :  5 Digits LCD
Outputs Provided :-
Resistance Range  :  0 400
Resolution :  0.1
Accuracy :  0.05%
PT-100 Sensor :  -200C to 850C
Resolution :  0.1C
Accuracy :  0.05%
Cu50 Sensor :  -200C to 150C
Resolution :  0.1C
Accuracy :  0.05%
Measuring Range :-
Resistance   :  0 TO 400
Resolution          :  0.1
Accuracy :  0.05%
PT 100 Sensor :  -200C to 850
Resolution :  0.1C
Accuracy :  0.05%
Cu50 Sensor :  -50C to 150C
Resolution :  0.1C
Accuracy :  0.05%

 



Wide Compatibility and Precision

Engineered to support multiple RTD types, the Metravi 03+ calibrator offers optimal flexibility within various calibration environments. Achieve high-precision simulations and calibrations for Pt, Cu, and Ni RTDs with a resolution of 0.1C and accuracy of 0.3C. The device's conformity to IEC751 for Pt100 and CE certification ensures globally recognized reliability.


Designed for Versatile Conditions

Whether you are working indoors or outdoors, the calibrator's robust design, lightweight form (approx. 350g), and handheld portability allow for seamless operation in laboratories, on-site field applications, and industrial environments. With an IP-rated durable build, it operates reliably across a wide temperature range and humidity up to 80% RH.


Efficient Operation and Long Battery Life

Featuring an intuitive LCD digital display, users can easily monitor readings during use. The 9V battery power offers continuous operation up to 40 hours, while special functions like low battery indication and overload protection enhance user experience and device longevity, making it perfectly suited for extended fieldwork.

FAQ's of Metravi 03+ RTD Calibrator:


Q: How do I use the Metravi 03+ RTD Calibrator for RTD simulation?

A: Connect your device using the 4-terminal banana sockets, select your desired output mode (direct or step), and choose the RTD type to simulate. Use the manual controls to set precise temperature values and verify outputs on the digital display for calibration or testing.

Q: What RTD sensor types does this calibrator support?

A: The calibrator supports Pt100, Pt200, Pt500, Pt1000, Cu50, Cu100, Ni100, and Ni120 sensor types, making it versatile for a variety of industrial and laboratory calibration tasks.

Q: Where can I use the Metravi 03+ RTD Calibrator?

A: It is engineered for both indoor and outdoor environments, suitable for laboratory setups, on-site industrial field calibration, or maintenance of automation systems, due to its rugged and portable design.

Q: What is the process for calibrating an RTD transmitter with this device?

A: To calibrate, connect the transmitter to the calibrator's terminals, select the corresponding RTD output type and desired temperature value, and use either the direct or step mode to simulate conditions. Monitor both devices' readings to complete the calibration process.

Q: What are the main benefits of the Metravi 03+ for users?

A: Users benefit from high accuracy (0.3C), portable design, broad RTD type compatibility, fast response time, long battery life, and additional features like low battery indication and overload protection, ensuring convenient and reliable operation in demanding conditions.

Q: When should I replace the battery and how is battery life indicated?

A: The calibrator has a low battery indication on its LCD, ensuring you are prompted before the power depletes. Under continuous operation, a fresh 9V battery powers the device for approximately 40 hours.

Q: What standards and safety compliance does the calibrator meet?

A: It complies with IEC751 for Pt100 sensor calibration and is CE certified, ensuring high standards for safety and performance in professional environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Calibrators Category

Metravi Ce-0102tmc Non-contact Tachometer Calibrator

Metravi Ce-0102tmc Non-contact Tachometer Calibrator

Display Type : 5 digit LCD

Humidity : 85% RH (noncondensing)

Control Mode : Manual

Equipment Type : Noncontact Tachometer Calibrator

Machine Weight : Approx. 800g

Accuracy : 0.02% of reading

Metravi 16+ Universal Thermocouple Signal Calibrator

Metravi 16+ Universal Thermocouple Signal Calibrator

Display Type : Large LCD Display

Humidity : <85% RH

Control Mode : Manual/Automatic

Equipment Type : Thermocouple Signal Calibrator

Machine Weight : Approx. 400g

Accuracy : (0.05% of reading + 2 digits)

Metravi 16+ Thermocouple Source & Calibration Device

Metravi 16+ Thermocouple Source & Calibration Device

Display Type : LCD Display

Humidity : 0~80% RH (noncondensing)

Control Mode : Manual

Equipment Type : Thermocouple Source & Calibration Device

Machine Weight : Approx. 250g

Accuracy : (0.5% rdg + 1C)

Metravi Calibrator

Metravi Calibrator

Display Type : LCD Digital Display

Humidity : <80% RH

Control Mode : Manual

Equipment Type : Calibrator

Machine Weight : 322g

Accuracy : (0.05%+2d)