About Metravi OS-5020 Dual Channel Oscilloscope
- Dual Trace Dual Channel Oscilloscope
- Bandwidth: 20MHz
- Full bandwidth sweeping circuit is used in the sweeping system
- The flexible and convenient triggering mode has the functions for selecting signals from one channel or triggered by Ext signals
- ALT trigger to observe signals from two irrelative channels
- The instrument has the functions of TV-H / TV-V synchronization and trigger-lock to observe all kinds of signals stably
- From the terminal for trigger input, CH1 and CH2 signals can be output along with the triggering channel to connect the Ext frequency counter
- Y deflection operation: Y1, Y2, ALT, CHOP, ADD, mode X-Y
- Vertical Deflection: 5mV/Div to 20V/Div in factor 1-2-5 sequence in 12 steps
- Rising time: < 18nS
- Maximum Input Voltage: 400V (DC +ACp-p)
- Triggering Source: Y1, Y2, ALT, POWER, EXT
- Trigger Coupling: AC/DC (EXT), NORM/TV-H, TV-V
- Horizontal Sweep Mode: AUTO, TRIG, LOCK, SINGLE
- Sweep time factor: 0.1uS/div to 0.2s/div in 1-2-5 sequence in 20 steps
- Magnification: x10
- X-Y Mode input: X-Axis YI and Y-Axis Y2
- Z Axis minimum input level: TTL Level
- Calibration Signal: Square wave of 0.5V at 1kHz
- CTR Display size: 8cm x 10cm
Dual Channel VersatilityWith two independent input channels, the OS-5020 enables simultaneous observation of separate signalsideal for comparative waveform analysis. This enhances troubleshooting in laboratories and service environments, supporting a range of electronic applications.
High Precision and Wide Measurement RangeOffering a vertical deflection from 5 mV/div to 5 V/div with fine 0.2 mV resolution and 3% accuracy, the Metravi OS-5020 facilitates precise signal measurement. Its time base covers 0.2 s/div to 0.5 s/div across 12 steps, suitable for various testing requirements.
Robust and User-Friendly DesignEquipped with a spacious CRT display and manual controls, the OS-5020 ensures clear visualization and intuitive operation. Its sturdy benchtop build, compliant with CE and IS 9001:2008 standards, guarantees reliability for both field and laboratory use.
FAQs of Metravi OS-5020 Dual Channel Oscilloscope:
Q: How do I set up and use the Metravi OS-5020 dual channel oscilloscope?
A: To set up the OS-5020, connect the supplied probes to the BNC input, power on using AC 220V 10%, and select your test signals. Adjust the vertical and horizontal controls, choose the desired trigger mode, and set input coupling (AC/DC/GND) as per your measurement needs. Refer to the included user manual for detailed start-up and measurement instructions.
Q: What are the key applications for the OS-5020 oscilloscope?
A: The OS-5020 is widely used for electronic signal monitoring, waveform analysis, laboratory measurements, and on-site field testing. Its dual channel capability supports circuitry diagnostics and component verification in education, research, and electronic service environments.
Q: When should I use horizontal magnification and trigger modes on this oscilloscope?
A: Use horizontal magnification (X10) for examining fast or intricate signal details. Trigger modesAuto, Normal, TV-V, and TV-Hhelp stabilize repetitive waveforms or capture specific events, enhancing analysis accuracy during testing.
Q: Where can I use the Metravi OS-5020 effectively?
A: This benchtop oscilloscope is suitable in laboratories, educational institutes, research settings, and for field engineers performing electronic maintenance or testing. Its portability and robust design make it ideal for both on-site evaluations and stationary lab work.
Q: What process does the OS-5020 follow to display electronic waveforms?
A: The oscilloscope converts input electrical signals into visual waveforms using a CRT display. The equipment processes signal amplitude through vertical deflection controls and time-based progression via horizontal sweep, triggered by selectable modes to ensure stable representations.
Q: What are the benefits of using this dual channel analog oscilloscope?
A: The OS-5020 offers simultaneous two-channel observation, precise measurement features, flexible triggering, and robust signal handling up to 400V. Its accuracy and ease of use make it a valuable asset for diagnostics, troubleshooting, and comprehensive waveform analysis.
Q: How does the Metravi OS-5020 ensure safety during operation?
A: The OS-5020 complies with CE and IS 9001:2008 safety standards, supports up to 400V maximum input (DC + AC peak), and includes insulated probes. Always follow the safety guidelines in the user manual for secure operation in varying environments and temperatures.